¹âÀǽ¤Î¥»¥ß¥ê¥¸¥Ã¥ÉƱ¼´¥±¡¼¥Ö¥ë¤Ç¤¹¡£EZ_141TP
À¤³¦¤Î°ìή¥á¡¼¥«¡¼¡ÖHUBER+SUHNER¡×¤Î¥±¡¼¥Ö¥ë¤Ç¤¹¡£
¥á¡¼¥«¡¼Àµµ¬¤Î¿·ÉʤǤ¹¡£
¥Þ¥¤¥¯¥íÇȼ¸³¡¢¥ß¥êÇȼ¸³¡¢¥ê¥Ë¥¢¥ó¥×¤ÎÇÛÀþ¡¢¥¢¥ó¥Æ¥Ê¤ÎºàÎÁ¤È¤·¤Æ¡¢Â¿ºÌ¤ÊÍøÍÑÊýË¡¤¬¤¢¤ê¤Þ¤¹¡£
£²£´£Ç£È£úÍѤ˺ÇŬ¤Ç¤¹¡£ºÇ¹â¼þÇÈ¿ô¡§33£Ç£È£ú
³°·Â3.58mm¤Î¡Ö141¡×¥¿¥¤¥×¤Ç¤¹¡£
1.ÆâÉôƳÂÎ ¶ä¥á¥Ã¥Æ¼¹ÝÀþ 092mm
2.Àä±ïÂÎ ¥Æ¥Õ¥í¥ó 2.98mm
3.³°ÉôƳÂÎ ¥¹¥º¥á¥Ã¥¥·¡¼¥à¥ì¥¹Æ¼´É 3.58mm
£°¡¥£µ£í¤Ç¥«¥Ã¥ÈÈÎÇ䤷¤Þ¤¹¡££µ£°£ã£íñ°Ì¡Ê¿¾¯¤ÎÀ£Ë¡¸íº¹¤¬Í¤ê¤Þ¤¹¡Ë
Electrical Data
Impedance: 50 Ω +/- 1
Max. operating frequency :33 GHz
Capacitance :98.1 pF/m
Velocity of signal propagation: 69.5 %
Signal delay :4.8 ns/m
Insulation resistance: ≥ 1 x 108 MΩm
Min. screening effectiveness: > 120 dB (up to 18 GHz)
Max. operating voltage: 1.9 kVrms (at sea level)
Test voltage: 5 kVrms (50 Hz/1 min)
Âбþ¥³¥Í¥¯¥¿¡¼¡§SMAP-402¡¢NP-141
HUBER+SUHNER
¤³¤Î¾¦ÉʤÏÂå¶â°ú´¹ÊؤϽÐÍè¤Þ¤»¤ó¡£